| Sector | abcEducation And Research Institute | Tender Value | N.A. | Location | Bihar - India | Ref.No | 66499837 | Closing Date | 07 - Dec - 2023 | | | Supply of Civil Engineering Laboratory (q3) Bench Top Meter for Measurement of Water Quality Parameters with All Accessories, Magnetic Stirrer with Hot Plate, Automatic Water Distillation Equipment Double Stage, Electronic Balance, Type of Electronic Weighing Machine Electronic Precision Pan, Balance, Rated Load/ Capacity(kg) 220 Gm, Resolution(gms) 1 Mg, Class Type Class-i, 1, Government Engineering College Khagaria, Civil Engineering Laboratory List of Equipment’s, Display Led, Number of Display Single, Speed of Measurement 4 Second, Number of Scale Division 1000, Tare Provision Manual, Power Requirement Mains Operated Battery Operated, Power Supply Single Phase, Dc Operating Voltage in Volts 6 Volt, Battery Backup Yes, Backup Time(hour) 10, Battery Type Non-rechargeable, Battery Rating Aaa1.5v, Type of Sensing Element Load Cell, Number of Load Cell/emfc 1, 5, Jar Test Apparatus, Flocculator, Unit Supplied with Glass Parts, Construction Ms Powder Coated, Heating Capacity of the Heater (watt) 500, Units of Test 6, Rotating Speed 10rpm to 150 Rpm, Power 230v , 50 Hz, Flask Capacities (ml) 1000, Electronic Display for the Speed and Temperature, Details of Other Accessories to Be Supplied Along with the Unit, Glass Parts, 1, 6, Fluoride Ion Meter, (with Fluoride, Electrode), Type/nomenclature/protection, Type of Meter/analyzer Bench Type, Functional Nomenclature Multi Parameter Water Quality, Analyzer, Ingress Protection(main Unit) Ip56, Calibration Automatic, Compensation/correction, Temperature Correction Automatic, Salinity Correction Automatic, Display/storage, Type of Display Lcd with Backlight, Display Digit Size 30 Milimeter, Number of Digits in Display 5, Number of Parameters Displayed Simultaneously 3, Memory (in Data Sets) 2000, Internal Memory (gb) 64, Date/time Stamp in Entries Yes, 1, 7, Double Beam Uvvis, Spectrophotome, Ter, Type, Type of Spectrophotometer Uv - Visible, Type of Optical System Double Beam, Monochromator Type Holographic Grating, Detector Type Photodiode, Spectral Bandwidth Type Fixed Bandwidth, 1, Government Engineering College Khagaria, Civil Engineering Laboratory List of Equipment’s, Light Source, Light Source Deuterium Lamp, Diffraction Grating (lines/mm)1400, Switching of Light Source Automatic, Wavelength Setting and Scanning Automatic, Optical Performance, Source Wavelength –minimum 190 Nanometer, Source Wavelength –maximum 1100 Nanometer, Resolution 0.3 Nanometer, Wavelength Accuracy (+/-) 0.5 Nanometer, Bandwidth (nm) 0.1, Scanning Speed(nm/min) 300, Focal Length (mm) 100 to 149, Photometric Measurement Modes Transmittance, Absorbance, , Concentration (wavelength, Time), Photometric Absorbance(max) (abs) (+/-) 3, Photometric Absorbance Accuracy (max) (+/-) 0.005, Photometric Transmittance (max) (+/-) 100 Percent, Photometric Transmittance Accuracy (max) (+/-) 0.1 Percent, Photometric Reflectance (max) (+/-) 0 Percent, Photometric Reflectance Accuracy (max) (+/-) 0.005 Percent, Baseline Correction Automatic, Generic, Display In-built Display, Display Type Lcd with Backlight, 8, Micropipette Single, Channel Fully, Autoclavable 0.5-5ml, Type of Micropipette Variable Volume Single Channel, Material of Piston Stainless Steel, Autoclavable Yes Digital Volume Indicator with, Other Details Conforming to Specification with Calibration, Certificate, Volume Range of Variable Volume Single Channel Pipette, 0.5ml -5ml, , Volume Increment (in Ul) 10, 3, 9 Prestaltic Pump, Flow Range – 0.1ml/hr to 1000ml/hr, Accuracy – ±2% Digital, Display of Functions and Time Auto-stop with Audible Alarm, Battery Back-up Stores Memory in Case of Power Failure., 1, 10 Portable Dissolved, Oxygen Meter, Measurement & Range Dissolved Oxygen - 0 to 20.0 Mg/l., Display 13 Mm (0.5") Lcd, 3 1/2 Digits. Accuracy ± 0.4 Mg/l., (after Calibration Within 23± 5?) Resolution 0.1 Mg/l, Power, Supply 006p Dc 9v Battery (heavy Duty Type)., 1, 11 High Volume Air, Sampler, Flow Rate 39 to 60 Cfm for Mfc; Typically 42 to 45 Cfm for Vfc;, Volumetric Flow Control Accuracy ±1% Deviation Over 24-hr, Period; Power Requirements 110/220 ± 10v, 100w; Precision, of Pressure Stabilization 0.05 Mpa, 1, 12 Ph Meter, 20 X 2 Line Back Lighted Lcd Display, Ph Meter Complies to Usp, and Din Standards, Alphanumeric Splash Waterproof Polyester, Keyboard with Soft Keys., Range 0° to 150° C., 1, 13 Turbidity Meter, 0 - 10, 000 Ntu , ± 2% of Reading Plus 0.01 Ntu (0 to 1000 Ntu), ± 5% of Reading (1000 to 4000 Ntu), ± 10% of Reading (4000 to 10, 000 Ntu) , Response Time Less, Than 6 Seconds, Sample Size 30ml, Operating Temperature 0° -, 50°c, 1, 14 Nessler Tube Borosilicate Glass, 3.3mm Thick, and 100ml Capacity 1, Government Engineering College Khagaria, Civil Engineering Laboratory List of Equipment’s, 15 Glass Test Tubes Made of Borosilicate 24, 16 Laboratory Hot Air, Oven, Digital Laboratory Oven (18''x18''x18''), Hot Oven 450mm Digital 1, 17 Thermometer Digit |
|
|